Chapter 4 Parameters|

4-48

Revision August 2008, 03VE, SW V2.04

75%

100%

Output Voltage

The maximum output voltage

reduction is 25%.

Auto Energy-saving Operation

Frequency

00-20

Source of the Master Frequency Command

Control

mode

VF VFPG SVC

FOCPG

Factory setting: 0

Settings

0

Digital

keypad

(KPV-CE01)

1

RS-485 serial communication

2

External analog input (Pr. 03-00)

3

External UP/DOWN terminal

4

Pulse input without direction command (Pr.10-15 without direction)

5

Pulse input with direction command (Pr.10-15)

This parameter determines the drive’s master frequency source.

00-21

Source of the Operation Command

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory setting: 0

Settings

0

Digital

keypad

(KPV-CE01)

1

External terminals. Keypad STOP disabled.

2

RS-485 serial communication (RJ-11). Keypad STOP disabled.

When Pr.00-21 is set to 1, it also needs to set Pr.00-20 and Pr.00-21 to 0. After pressing PU

key to make LED PU to be light, RUN, JOG and STOP key are valid now.




00-22

Stop Method

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory setting: 0

Settings

0

Ramp to stop

1

Coast to stop