Chapter 4 Parameters|

4-134

Revision August 2008, 03VE, SW V2.04

Control

mode

VF VFPG SVC

FOCPG

Factory Setting: 100

Settings 0~100%

The corresponding value for the 100% of dancer is 10V.

08-64

Allowance Error Detection Time of Tension PID Feedback

Unit: 0.1

Control

mode

VF VFPG SVC

FOCPG

Factory Setting: 0.5

Settings 0.0~10.0

sec

08-65

Error Treatment of Tension PID Feedback

Control

mode

VF VFPG SVC

FOCPG

Factory Setting: 0

Settings

0

Warn and keep operation

1

Warn and coast to stop

2

Warn and ramp to stop

When the error of tension PID target value and tension PID feedback exceeds Pr.08-63 and

the allowance error detection time of tension PID exceeds Pr.08-64, tension PID feedback

error occurs. Refer to Pr.08-65 for error treatment of tension PID feedback.

08-66

Upper Limit of Tension PID Feedback

Unit: 0.1

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory Setting: 100.0

Settings 0.0~100.0%

08-67

Lower Limit of Tension PID Feedback

Unit: 0.1

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory Setting: 0.0

Settings 0.0~100.0%

08-68

Reserved

08-69

DFM Selection

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory Setting: 0

Settings

0

Output

frequency

1

Frequency

command

08-70

Low-pass Filter Time of Line Speed

Unit: 0.01

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory Setting: 0.00