Chapter 4 Parameters|

Revision August 2008, 03VE, SW V2.04

4-129

3

Pulse

input

(Pr.08-40)

4

DFM-DCM pulse input (Pr.02-18)

When it is set to 1, 3 or 4, the current line speed will be saved into Pr.08-41 via analog and

pulse command. When it is set to 2, it can change the setting of Pr.08-41 (current line speed)

via communication.

When it is set to 3 or 4, pulse signal needs to be connected to PG2 of the PG card and then

set the PG type by Pr.10-15.

When it is set to 3, it needs to use with Pr.08-40.

When it is set to 4, Pr.02-18 setting needs to be set to the DFM output value of previous driver

as shown in the following before setting Pr.08-38.

T P

DFM

DF M

(02-18)

DCM

T P

AB2

A2
/A2
B2
/B2
DCM

PG 2

tractor

motor

motor

Driv er 1

Driv er 2

the setting of P r,02-18 of motor 2
= the setti ng of Pr.02-18 of m otor 1

Pr.10- 15 of motor 2
should be set to 3 or 4

Wind



08-38

Max. Line Speed

Unit: 0.1

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory Setting: 1000.0

Settings

0.0 to 3000.0 m/min

08-39

Min. Line Speed

Unit: 0.1