background image

Chapter 6 Fault Code Information and Maintenance|

Revision August 2008, 03VE, SW V2.04

6-11

„

Printed circuit board and connector of main circuit

Maintenance

Period

Check Items

Methods and Criterion

Daily

Half

Year

One

Year

If there are any loose screws and
connectors

Tighten the screws and press the
connectors firmly in place.

{

If there is any peculiar smell and
color change

Visual inspection

{

If there is any crack, damage,
deformation or corrosion

Visual inspection

{

If there is any liquid is leaked or
deformation in capacity

Visual inspection

{

„

Cooling fan of cooling system

Maintenance

Period

Check Items

Methods and Criterion

Daily

Half

Year

One

Year

If there is any abnormal sound or
vibration

Visual, aural inspection and turn the
fan with hand (turn off the power
before operation) to see if it rotates
smoothly

{

If there is any loose screw

Tighten the screw

{

If there is any color change due to
overheat

Change fan

{

„

Ventilation channel of cooling system

Maintenance

Period

Check Items

Methods and Criterion

Daily

Half

Year

One

Year

If there is any obstruction in the
heat sink, air intake or air outlet

Visual inspection

{