beautypg.com

13 electromagnetic/induction noise, 14 environmental condition, 13 electromagnetic/induction noise -9 – Delta Electronics AC Motor Drive VFD-VE Series User Manual

Page 224: 14 environmental condition -9

background image

Chapter 5 Troubleshooting|

Revision August 2008, 03VE, SW V2.04

5-9

5.13 Electromagnetic/Induction Noise

There are many noises surround the AC motor drives and invade it by radiation or power circuit. It

may cause the misoperation of control circuit and even damage the AC motor drive. Of course, that
is a solution to increase the noise tolerance of AC motor drive. But it is not the best one due to the
limit. Therefore, solve it from the outside as following will be the best.

1.

Add surge killer on the relay or contact to suppress switching surge between ON/OFF.

2.

Shorten the wiring length of the control circuit or serial circuit and separate from the main

circuit wiring.

3.

Comply with the wiring regulation for those shielded wire and use isolation amplifier for

long wire.

4.

The grounding terminal should comply with the local regulation and ground independently,

i.e. not to have common ground with electric welding machine and power equipment.

5.

Connect a noise filter at the input terminal of the AC motor drive to prevent noise from

power circuit.

In a word, three-level solutions for electromagnetic noise are “no product”, “no spread” and
“no receive”.

5.14 Environmental Condition

Since AC motor drive is an electronic device, you should comply with the environmental condition

stated in the appendix A. Following are the remedial measures for necessary.

1.

To prevent vibration, anti-vibration spacer is the last choice. The vibration tolerance must

be within the specification. The vibration effect is equal to the mechanical stress and it

cannot occur frequently, continuously or repeatedly to prevent damaging AC motor drive.

2.

Store in a clean and dry location free from corrosive fumes/dust to prevent rustiness, poor

contact. It also may cause short by low insulation in a humid location. The solution is to

use both paint and dust-proof. For particular occasion, use the enclosure with whole-seal

structure.

3.

The surrounding temperature should be within the specification. Too high or low

temperature will affect the lifetime and reliability. For semiconductor components, damage

will occur once any specification is out of range. Therefore, it is necessary to clean and

periodical check for the air cleaner and cooling fan besides having cooler and sunshade.

In additional, the microcomputer may not work in extreme low temperature and needs to

have heater.