Chapter 4 Parameters|

4-46

Revision August 2008, 03VE, SW V2.04

When Pr.00-13 is set to 0.

1
2

01-00

01-12

01-14

01-16

01-18

01-13

01-15

01-17

01-19

01-05

1

2

Frequency

Max.

Frequency

Min.

Frequency

accel. time

Time

decel. time

Accel./Decel. Time

When Pr.00-13 is set to 3.

00-14

Time Unit for Acceleration/Deceleration and S Curve

Control

mode

VF VFPG SVC

FOCPG

Factory setting: 0

Settings

0

Unit:

0.01

second

1

Unit:

0.1

second

This parameter determines the time unit for the Acceleration/Deceleration setting. Refer to

Pr.01-12 ~ Pr.01-19 (accel./decel. Time 1 to 4), Pr. 01-20~Pr.01-21 (JOG accel./decel. Time)

and Pr. 01-24~Pr.01-27 (S curve accel./decel. Time).

00-15

Reserved

00-16

Reserved

00-17

Carrier Frequency

Unit: 1

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory setting: 10

Settings

1~15kHz

This parameter determinates the PWM carrier frequency of the AC motor drive.


230V/460V Series

Models

1-5HP

0.75-3.7kW

7.5-25HP

5.5-18.5kW

30-60HP

22-45kW

75-100HP

55-75Kw

Setting Range

01~15kHz 01~15kHz 01~09kHz

01~06kHz

Factory Setting

10kHz

9kHz 6kHz 6kHz

1kHz

8kHz

15kHz

Carrier

Frequency

Acoustic

Noise

Electromagnetic

Noise or Leakage

Current

Heat

Dissipation

Current

Wave

Significant

Minimal

Minimal

Minimal

Significant

Significant