Chapter 4 Parameters|

Revision August 2008, 03VE, SW V2.04

4-133

Settings

0.0~100.0% (according to Pr.08-26)

08-57

Frequency for Smart Start

Unit: 1

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory Setting: 2.00

Settings 0.00~600.00Hz

08-58

Accel. Time for Smart Start

Unit: 0.01

Control

mode

VF VFPG SVC

FOCPG

Factory Setting: 3.00

Settings 0.01~600.00

sec

When the speeds of wider/unwinder and tractor can’t match at start-up, the situation can be

improved by setting Pr.08-57 and Pr.08-58.

08-59

Broken Belt Detection

Control

mode

VF VFPG SVC

FOCPG

Factory Setting: 0

Settings

0

Disable

1

Enable

08-60

Min. Line Speed of Broken Belt Detection

Unit: 0.1

Control

mode

VF VFPG SVC

FOCPG

Factory Setting: 0.0

Settings 0.0~3000.0

m/min



08-61

Allowance Error of Line Speed of Broken Belt Detection

Unit: 0.1

Control

mode

VF VFPG SVC

FOCPG

Factory Setting: 100.0

Settings 1.0~6000.0

mm

08-62

Detection Time of Broken Belt

Unit: 0.1

Control

mode

VF VFPG SVC

FOCPG

Factory Setting: 1.00

Settings 0.00~100.00

sec

When the broken belt detection is enabled, line speed is higher then Pr.08-61, allowance error

of line speed of broken belt detection exceeds Pr.08-61 and detection time of broken belt

exceeds Pr.08-62, the broken belt occurs.

08-63

Allowance Error Level of Tension/Line Speed PID Feedback

Unit: 1