Chapter 4 Parameters|
4-132
Revision August 2008, 03VE, SW V2.04
Control
mode
VF VFPG SVC
FOCPG TQRPG
Factory Setting: 1
Settings
1 to 10000ppr
08-50
Coil Number for Each Layer
Unit: 1
Control
mode
VF VFPG SVC
FOCPG TQRPG
Factory Setting: 1
Settings
1 to 10000
08-51
Material Thickness
Unit: 0.001
Control
mode
VF VFPG SVC
FOCPG TQRPG
Factory Setting: 1.000
Settings
0.001 to 60.000mm
08-52
Filter Time of Reel Diameter
Unit: 0.01
Control
mode
VF VFPG SVC
FOCPG TQRPG
Factory Setting: 1.00
Settings
0.00 to 100.00 sec
This parameter can be used to improve unstable of the source of reel diameter(Pr.08-42).
08-53
Auto Compensation of Reel Diameter
Control
mode
VF VFPG SVC
FOCPG TQRPG
Factory Setting: 0
Settings
0
Disable
1
Enable
08-54
Current Reel Diameter
Unit: 0.1
Control
mode
VF VFPG SVC
FOCPG TQRPG
Factory Setting: 1.0
Settings
1.0 to 6000.0 mm
When the AC motor drive is not at STOP, this parameter is read-only.
08-55
Smart Start
Control
mode
VF VFPG SVC
FOCPG TQRPG
Factory Setting: 0
Settings
0
Disable
1
Enable
2
In unwind mode, rewind in reverse direction
08-56
Switch Level for Smart Start and PID Function
Unit: 1
Control
mode
VF VFPG SVC
FOCPG TQRPG
Factory Setting: 15.0