beautypg.com

Delta Electronics AC Motor Drive VFD-VE Series User Manual

Page 57

background image

Chapter 4 Parameters|

4-8

Revision August 2008, 03VE, SW V2.04

Pr.

Explanation

Settings

Factory

Setting

VF VFPG SVC FOCPG TQRPG

44: Max. reel diameter attained

45: Empty reel diameter attained

46: Broken belt detection

47: Break release at stop

48: Error PID feedback of tension

49: Reserved

50: Reserved

02-15

Multi-output Direction

0 ~ 65535

0

02-16

Terminal Count Value

0 ~ 65535

0

02-17

Preliminary Counter
Value

0 ~ 65535

0

02-18

Digital Output Gain

1 ~ 40

1

02-19

Desired Frequency
Attained 1

0.00 ~ 600.00Hz

60.00/

50.00

02-20

The Width of the Desired
Frequency Attained 1

0.00 ~ 600.00Hz

2.00

02-21

Desired Frequency
Attained 2

0.00 ~ 600.00Hz

60.00/

50.00

02-22

The Width of the Desired
Frequency Attained 2

0.00 ~ 600.00Hz

2.00

02-31

Brake Delay Time

0.000~65.000 Sec

0.000

02-32

Output Current Level
Setting for External
Terminals

0~100%

0

02-33

Output Boundary for
External Terminals

0.00~+-60.00Hz (it is motor speed when using PG)

0.00

02-34

External Operation
Control Selection after
Reset

0: Disable
1: Drive runs if run command exists after reset

0

02-43

Zero-speed Level of
Motor

0~65535 rpm

0