Air Temperature:

-10 ~ +40°C (14 ~ 122°F)

Relative Humidity:

<90%, no condensation allowed

Atmosphere
pressure:

86 ~ 106 kPa

Installation Site
Altitude:

<1000m

Operation

Vibration:

<20Hz: 9.80 m/s

2

(1G) max

20 ~ 50Hz: 5.88 m/s

2

(0.6G) max

Temperature: -20°C

~

+60°C (-4°F ~ 140°F)

Relative Humidity:

<90%, no condensation allowed

Atmosphere
pressure:

86 ~ 106 kPa

Storage

Transportation

Vibration:

<20Hz: 9.80 m/s

2

(1G) max

20 ~ 50Hz: 5.88 m/s

2

(0.6G) max

Pollution Degree 2: good for a factory type environment.


Minimum Mounting Clearances

H

DATA

PROG

RE V

FWD

Air Flow

H

W

W

HP

W

mm (inch)

H

mm (inch)

1-5HP

50 (2)

150 (6)

7.5-20HP

75 (3)

175 (7)

25-75HP

75 (3)

200 (8)

100HP and above

75 (3)

250 (10)