Chapter 4 Parameters|

4-128

Revision August 2008, 03VE, SW V2.04

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory Setting: 50.0

Settings 0.0

to

1000.0

08-30

Tension PID I1

Unit: 0.01

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory Setting: 1.00

Settings

0.00 to 500.00 sec

08-31

Reserved

08-32

Tension PID P2

Unit: 0.1

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory Setting: 50.0

Settings 0.0

to

1000.0

08-33

Tension PID I2

Unit: 0.01

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory Setting: 1.00

Settings

0.00 to 500.00 sec

08-34

Reserved

08-35

PID Output Status

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory Setting: 0

Settings

0

Positive

output

1

Negative

output

08-36

Tension/Line Speed PID Output Limit

Unit: 0.01

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory Setting: 20.00

Settings

0 to 100.00% (according to Pr.01-00)




08-37

Source of Line Speed Input Command

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory Setting: 0

Settings

0

Disable

1

Analog input (Pr. 03-00~03-02 is set to 12 line speed)

2

RS-485 communication setting (Pr.08-41)