10-02

PG Feedback Fault Treatment

Control

mode

VFPG

FOCPG

TQRPG

Factory Setting: 2

Settings

0

Warn and keep operating

1

Warn and RAMP to stop

2

Warn and COAST to stop

10-03

Detection Time for PG Feedback Fault

Unit: 0.01

Control

mode

VFPG

FOCPG

TQRPG

Factory Setting: 1.00

Settings

0.00 to 10.00 sec

When PG loss, encoder signal error, pulse signal setting error or signal error, if time exceeds

the detection time for PG feedback fault (Pr.10-03), the PG signal error will occur. Refer to the

Pr.10-02 for PG feedback fault treatment.

10-04

ASR (Auto Speed Regulation) control (P) 1

Unit: 0.1

Control

mode

VFPG

FOCPG

Factory Setting: 10

Settings

0 to 40 Hz

10-05

ASR (Auto Speed Regulation) control (I) 1

Unit: 0.001

Control

mode

VFPG

FOCPG

Factory Setting: 0.100

Settings

0.000 to 10.000 sec

10-06

ASR (Auto Speed Regulation) control (P) 2

Unit: 0.1

Control

mode

VFPG

FOCPG

Factory Setting: 10

Settings

0 to 40Hz

10-07

ASR (Auto Speed Regulation) control (I) 2

Unit: 0.001

Control

mode

VFPG

FOCPG

Factory Setting: 0.100

Settings

0.000 to 10.000 sec

10-08

ASR 1/ASR2 Switch Frequency

Unit: 0.01

Control

mode

VFPG

FOCPG

Factory Setting: 7.00

Settings

5.00 o 600.00Hz

ASR P determines Proportional control and associated gain (P). ASR I determines integral

control and associated gain (I).