Delta Electronics AC Motor Drive VFD-VE Series User Manual

Page 148

background image

Chapter 4 Parameters|

Revision August 2008, 03VE, SW V2.04

4-99

5%

Pr.06-07,
Pr.06-10

Pr.06-08, 06-11

current

06-12

Current Limit

Unit: 1

Control

mode

FOCPG

TQRPG

Factory Setting: 150

Settings

0 to 250%

It is used to set the current limit.

06-13

Electronic Thermal Relay Selection (Motor 1)

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory Setting: 2

Settings

0

Operate with a Inverter Motor (forced external cooling)

1

Operate with a Standard Motor (self-cooled by fan)

2

Disabled

06-27

Electronic Thermal Relay Selection (Motor 2)

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory Setting: 2

Settings

0

Operate with a Inverter Motor (forced external cooling)

1

Operate with a Standard Motor (self-cooled by fan)

2

Disabled

It is used to prevent self-cooled motor overheats under low speed. User can use electrical

thermal relay to limit driver’s output power.

06-14

Electronic Thermal Characteristic for Motor 1

Unit: 0.1

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory Setting: 60.0

Settings

30.0 to 600.0 sec

06-28

Electronic Thermal Characteristic for Motor 2

Unit: 0.1

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory Setting: 60.0

Settings

30.0 to 600.0 sec