Chapter 4 Parameters|

Revision August 2008, 03VE, SW V2.04

4-105

Bit0

Bit1

Bit2

Bit3

Bit4

Bit5

Bit6

Fault code

current Volt.

OL

SYS

FBK

EXI

CE

50: Emergency stop (EF1)

51: External Base Block (B.B.)

52: Password error (PcodE)

53: Reserved

54: Communication error (cE1)

55: Communication error (cE2)

56: Communication error (cE3)

57: Communication error (cE4)

58: Communication Time-out
(cE10)

59: PU time-out (cP10)

60: Brake transistor error (bF)

61: Y-connection/

Δ-connection

switch error (ydc)

62: Decel. Energy Backup Error
(dEb)

63: Slip error (oSL)

64: Broken belt error (bEb)

65: Error PID feedback signal of
tension (tdEv)

06-29

PTC (Positive Temperature Coefficient) Detection Selection

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory Setting: 0

Settings

0

Warn and keep operating

1

Warn and ramp to stop

2

Warn and coast to stop

It is used to set the treatment after detecting PTC.


06-30

PTC Level

Unit: 0.1

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory Setting: 50.0