beautypg.com

Delta Electronics AC Motor Drive VFD-VE Series User Manual

Page 129

background image

Chapter 4 Parameters|

4-80

Revision August 2008, 03VE, SW V2.04

Positive torque

Reverse

03-00~02=7

Positive torque limit

03-00~02=8

Negative torque limit

03-00~02=9

Regenerative
torque limit

03-00~02=10

Positive/negative torque limit

Negative Torque

Forward

03-00~02=10

Positive/negative torque limit

03-00~02=9

Regenerative
torque limit

03-03

Analog Input Bias 1 (AVI)

Unit: 0.1

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory setting: 0

Settings

-100.0~100.0%

It is used to set the corresponding AVI voltage of the external analog input 0.

03-04

Analog Input Bias 1 (ACI)

Unit: 0.1

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory setting: 0

Settings -100.0~100.0%

It is used to set the corresponding ACI voltage of the external analog input 0.

03-05

Analog Input Bias 1 (AUI)

Unit: 0.1

Control

mode

VF VFPG SVC

FOCPG TQRPG

Factory setting: 0

Settings -100.0~100.0%

It is used to set the corresponding AUI voltage of the external analog input 0.








03-06

Positive/negative Bias Mode (AVI)

03-07

Positive/negative Bias Mode (ACI)

03-08

Positive/negative Bias Mode (AUI)