beautypg.com

Delta Electronics AC Motor Drive VFD-VE Series User Manual

Page 234

background image

Chapter 6 Fault Code Information and Maintenance|

Revision August 2008, 03VE, SW V2.04

6-9

Maintenance

Period

Check Items

Methods and Criterion

Daily

Half

Year

One

Year

If there is any color change by
overheating

Visual inspection

{

If there is any dust or dirt Visual

inspection

{

„

Main circuit

Maintenance

Period

Check Items

Methods and Criterion

Daily

Half

Year

One

Year

If there are any loose or missing
screws

Tighten or replace the screw

{

If machine or insulator is
deformed, cracked, damaged or
with color change due to
overheating or ageing

Visual inspection

NOTE: Please ignore the color

change of copper plate

{

If there is any dust or dirt Visual

inspection

{

„

Terminals and wiring of main circuit

Maintenance

Period

Check Items

Methods and Criterion

Daily

Half

Year

One

Year

If the terminal or the plate is
color change or deformation due
to overheat

Visual inspection

{

If the insulator of wiring is
damaged or color change

Visual inspection

{

If there is any damage

Visual inspection

{