beautypg.com

Welch Allyn 901061 Propaq LT Vital Signs Monitor - User Manual User Manual

Page 87

background image

Directions for Use

Alarms and alerts

83

If it is configured to Always On and you set Suspend Audible Alarms to On,
then the alarm tone remains suspended until:

you set Suspend Audible Alarms to Off or

monitor power is turned off and then turned on again or

the monitor is reconfigured

To suspend the alarm tone

1.

Access the Setup menu. (See

“To access the setup menus”

on page 37.)

2.

Highlight Suspend Audible Alarms).

Figure 88. Suspend Audible Alarms: Off

The configured suspension period—90 seconds in this example—is displayed to the
right of the line.

3.

Highlight On.

Figure 89. Suspend Audible Alarms: On

The alarm tone is suspended immediately.

If an alarm condition occurs during the suspension period, the alarm tone does
not sound.

Note

Suspend Audible Alarms does not affect the behavior of the alarm silence/
reset
feature (

). Pressing

always either silences a sounding alarm tone for 90

seconds or resets the audible alarm if it was already silenced.

Note

If audible alarms are suspended, pressing

cancels the suspension.

II 1mV/cm

II 1mV/cm

Exit

Exit

Trends

Trends

Snapshots

Snapshots

Setup

Setup

Low

Low

Med

Med

HR/min

HR/min

NIBP mmHg

NIBP mmHg

Resp/min

Resp/min

SpO2

SpO2

Off

Off

On

On

Alarm Tone

Alarm Tone

Suspend Audible Alarms

Suspend Audible Alarms

Setup

Setup

(90 sec)

(90 sec)

%

%

3:00:06P

3:00:06P

Adult

Adult

Rm 239

Rm 239

Alarms

Alarms

ECG

ECG NIBP

NIBP Timings

Timings

High

High

Configuration

Configuration

HALL, ROBERT E.

HALL, ROBERT E.

3456187

3456187

Right ( ) to suspend audible alarms.

Right ( ) to suspend audible alarms.

Service

Service

II 1mV/cm

II 1mV/cm

Exit

Exit

Trends

Trends

Snapshots

Snapshots

Setup

Setup

Low

Low

Med

Med

80

80

HR/min

HR/min

NIBP mmHg

NIBP mmHg

Resp/min

Resp/min

SpO2

SpO2

Off

Off

On

On

Alarm Tone

Alarm Tone

Suspend Audible Alarms

Suspend Audible Alarms

Setup

Setup

(90 sec)

(90 sec)

12

12

97

97

%

%

8765432

8765432

3:00:06P

3:00:06P

Adult

Adult

Rm 239

Rm 239

Alarms

Alarms

ECG

ECG NIBP

NIBP Timings

Timings

High

High

Service

Service

0:01:30 remaining

0:01:30 remaining

Audio alarms suspended

Audio alarms suspended

ID: 01018VDO9PBH

ID: 01018VDO9PBH

Configuration

Configuration

‘Tone suspended’ indicator

Suspension time remaining

Configured suspension period