Welch Allyn 901061 Propaq LT Vital Signs Monitor - User Manual User Manual
Page 7

Directions for Use
Introduction
3
(red)
The battery is near failure; the monitor will shut down soon. If this indicator appears
while the monitor is in the cradle, the battery cannot be charged and must be replaced.
The battery is near failure and is charging. The monitor will shut down if removed from the cradle.
The monitor is communicating wirelessly with the network and with Acuity. (Wireless only, Acuity
enabled.)
The monitor is not communicating with the wireless network. (Wireless only, Acuity enabled.)
(Flashing) The monitor is communicating with the network but is not communicating with Acuity.
(Wireless only, Acuity enabled.)
The monitor is communicating by USB cable with a PC.
Cradle
(green) Cradle is powered.
(green) Monitor battery is charging.
NOTE: When the battery is fully charged, this indicator is not lit.
(yellow) Cradle fault or battery fault.
Table 4. Labels
Monitor
Proceed with caution. If in doubt, refer to the
accompanying documentation.
Enclosure protection: Drip
-
proof. Class IPX1
per EN60529:1991.
The monitor or accessory meets all essential
requirements of the European Medical Device
Directive 93/42/EEC for a Class II-b product.
The monitor is certified by the Canadian
Standards Association International to comply
with applicable US and Canadian medical
safety standards.
The monitor or accessory meets all essential
requirements of the European Medical Device
Directive 93/42/EEC for a Class I product.
Type CF patient connections, isolated for direct
cardiac application and protected against
defibrillation.
Australian registered importer.
Hazard Class 9, IATA/ICAO (International Air
Transport Association/International Civil
Aviation Organization).
Professional use only
This device complies with the 47 CFR Part 15
radiated and conducted emissions
requirements.
This device complies with FCC and Industry Canada requirements for international
radiators (802.11 wireless).
See the accompanying manual.
Non-ionizing electromagnetic radiation. This
device contains an approved RLAN module of
frequency 5150-5825 MHz.
Reorder number
Product identifier
separately from other waste. (Refer to
for collection-
point and additional information.)
Non-ionizing electromagnetic radiation. This
device contains an approved RLAN module of
frequency 2402-2480 MHz. (Wireless only,
Acuity enabled; see
Table 3. Status indicators (continued)
N344
FCC ID: PGUWA11A07
IC:4168a-WA11A07