What’s New in Each Version • New Features
411
Publication 1398-PM601A-EN-P — October 2000
APPENDIXES
Changes to Version 3.0 from Version 2.1
•
Support for IQ Cam
•
Tracking function enhancement to electronic gearing
•
Compiler options program statements
•
Off-line parameter editing
•
DDE Server capability
•
Support for redefining key codes for generic operator terminals
•
Support for connecting one Operator Terminal to multiple IQs
•
Movecomplete and Jogactive system flags
•
Toolbar button for File Transfer
Changes to Version 2.1 from Version 2.xx
•
Support for the IQ-550 Position Control Module
•
Support for a generic operator terminal
•
Default File Extension changes - all IQ files begin with “Q”
•
Toolbar buttons
•
Context Sensitive Help
•
Replace function added to the editor
•
Ability to monitor G and V variables
•
Ability to directly save a file to the IQ after successful compile
Changes to Version 2.0 from Version 1.xx
•
Multiple statements may be on one line:
START: V1=2.5 G1=V1*3.1 X3 CONT MD=G13 JUMP MAIN
•
Statements may be continued on multiple lines:
IF F1 = ON
G1 = POS2 ELSE G1 = POS1
•
Multiple statements may be treated as a group when contained in curly braces:
IF F1=ON {O1=ON G1=POS2}
•
Multiple statements in curly braces can also be used in scanned events:
S1: IF F1=ON {O2=ON G1=POS2 F2=OFF}
•
Two new programming statements have been added:
DO statement WHILE condition example: DO V1=V1+1 WHILE I12=ON
WHILE condition statements example: WHILE I12=ON {V1=V1+1 G3=V1+2}
•
Two additional variables have been added for positions captured on occurrence of an index pulse:
IX1P2 (POS2 on index 1) and IX2P1 (POS1 on index 2).
V1 = IX1P2
G2 = IX2P1
•
The ERETPOS variable for the emergency return position parameter may now also be called
EPOS.
V1 = ERETPOS
G2 = EPOS
•
Two variables have been added to allow setting the present jog acceleration and jog deceleration
parameters without changing the nonvolatile parameter values: