Language Reference • Reference
Publication 1398-PM601A-EN-P — October 2000
WORDS
SYSWARN
Cause System Warning
System
Purpose
Used to cause a system warning. If set to a value, a system warning occurs.
Syntax
SYSWARN= value
value
Value can be a constant, a nonvolatile Gn, a volatile Vn, or
another system variable.
Remarks
This command takes effect only when the Disable on Fault parameter is set to Partial.
Refer to Part 2
•
IQ Master Environment, Parameter menu, System for more informa-
tion on the Disable on Fault parameter.
See Also
EFLAG, ENUM, WFLAG, WNUM, SYSERROR
Example
SYSWARN = 33
;will cause an ’IAVG Fault’ Warning
TBASE
Timebase
System
Purpose
Indicates the number of position loop updates (2mS) in one unit of time. The unit of
time is the Timebase and is set the Parameter menu, Velocity/ Accel dialog box.
Syntax
variable = TBASE
variable
Variable can be a nonvolatile variable Gn, a volatile variable
Vn, or another system variable.
A value of 500 indicates the Timebase is in seconds. A value of
30,000 indicates a Timebase of minutes.
Remarks
This variable may be used in a program to determine if velocity units are per minute or
per second.
See Also
Example
V3 = TBASE
TIMERn
Timer
Scanned Events
Purpose
Load TIMERn with the time specified in this instruction, or read the present value.
Syntax
TIMERn = time
variable = TIMERn
n
The number of the timer: n = 1 or 2.
time
The time is entered in seconds regardless of the setting of the
user Timebase. Time can be a constant, a nonvolatile variable
Gn, a volatile variable Vn, or a system variable
variable
The variable can be a nonvolatile variable Gn, a volatile variable
Vn, or another system variable.
Remarks
Timers have a resolution of .002 seconds (2 ms).
See Also
Sn: TMR