Hardware reset, Monitor fvel1, Monitor pfe – Rockwell Automation 1398-PDM-xxx IQ Master Version 3.2.4 for IA-2000 and IQ-5000 Positioning Drive Modules, IQ-55 User Manual
Page 379: Monitor picmd, Monitor pos1, Monitor pos2, Monitor pvel1

Optional Operator Terminal Function Key Programs • Hardware Reset
357
Publication 1398-PM601A-EN-P — October 2000
APPENDIXES
Hardware Reset
This program, HRESET.QPS, performs a Hardware Reset of the ULTRA Plus or IQ.
Monitor FVEL1
This program, MONFVEL1.QPS, sets the system variable OTMON to the proper value which displays
the system variable FVEL1 on the top line of the Operator Terminal screen. This display is continuously
updated. If this program is run again, the display will be cleared. If other Fkey programs using OTMON
are run, the display will switch to monitor the proper variable.
Monitor PFE
This program, MDNPFE.QPS, sets the system variable OTMON to the proper value which displays the
system variable PFE on the top line of the Operator Terminal screen. This display is continuously
updated. If this program is run again, the display will be cleared. If other Fkey programs using OTMON
are run, the display will switch to monitor the proper variable.
Monitor PICMD
This program, MONPICMD.QPS, sets the system variable OTMON to the proper value which displays
the system variable PICMD on the top line of the Operator Terminal screen. This display is continu-
ously updated. If this program is run again, the display will be cleared. If other Fkey programs using
OTMON are run, the display will switch to monitor the proper variable.
Monitor POS1
This program, MONPOS1.QPS, sets the system variable OTMON to the proper value which displays
the system variable POS1 on the top line of the Operator Terminal screen. This display is continuously
updated. If this program is run again, the display will be cleared. If other Fkey programs using OTMON
are run, the display will switch to monitor the proper variable.
Monitor POS2
This program, MONPOS2.QPS, sets the system variable OTMON to the proper value which displays
the system variable POS2 on the top line of the Operator Terminal screen. This display is continuously
updated. If this program is run again, the display will be cleared. If other Fkey programs using OTMON
are run, the display will switch to monitor the proper variable.
Monitor PVEL1
This program, MONPVEL1.QPS, sets the system variable OTMON to the proper value which displays
the system variable PVEL1 on the top line of the Operator Terminal screen. This display is continuously
updated. If this program is run again, the display will be cleared. If other Fkey programs using OTMON