HP NetRAID-4M Controller User Manual
Page 95

5-17
Working with Disksets
HPN0> disk_set list
Executing: disk_set list
Diskset ID Creator ID Owner
------------------- ------------------ ------------------
0x01be868c1d74a640 0xfafaf001007a1c00 \\.\HPN0
Disks Attached OS Managed Label Shared Spare
------ -------- ---------- ---------- ------ -----
3 NO NO Saturn YES NO
To assign MSCS management of a diskset, use the
disk_set
OSmanaged
command with the
/false
switch, as in the following
example. In the example, the /false switch assigns MSCS
management to the diskset whose diskset ID is 0x01be868c1d74a640
and whose creator ID is 0xfafaf001007a1c00.
HPN0>
disk_set OSmanaged
/false=FALSE 0x01be868c1d74a640
0xfafaf001007a1c00
Executing: disk_set OSmanaged /false=FALSE
681,522,135,130,238,977 -361,712,932,956,267,520
After running the
disk_set OSmanaged
command to assign
MSCS management to a diskset, use the
disk_set list
command
to display information about your disksets, as in the following
example. In the example, the OSmanaged column indicates YES,
which means that the diskset is managed by the MSCS. Note that the
example alters the
disk_set list
output so that the data can fit
on the page.
HPN0> disk_set list
Executing: disk_set list
Diskset ID Creator ID Owner
------------------- ------------------ ------------------
0x01be868c1d74a640 0xfafaf001007a1c00 \\.\HPN0
Disks Attached OS Managed Label Shared Spare
------ -------- ---------- ---------- ------ -----
3 NO YES Saturn YES NO