Managing flash eprom components, Managing flash eprom components 3-18 – HP NetRAID-4M Controller User Manual
Page 42

3-18
Command Line Interface User’s Guide
Caution:
The controller deletes any data on the replacement
disk when automatic spare is enabled and you remove the
failed disk and insert the replacement disk in the failed
disk’s slot.
Note:
The automatic spare feature works only with disks
that reside in a SAF-TE enclosure management device.
The CLI allows you to do the following:
■
Display a controller’s automatic spare status
■
Enable automatic spare
To display a controller’s automatic spare status, use the
controller show automatic_spare
command, as in the
following example. In the example, the automatic spare feature is
indicated as DISABLED.
HPN0> controller show automatic_
spare
Executing: controller show automatic_
spare
Automatic
spare
DISABLED
To enable automatic spare, use the
controller set
automatic_spare
command with the
/
spare
switch, as in the
following example:
HPN0> controller set automatic_spare /spare_enabled=TRUE
Executing: controller set automatic_spare /spare_enabled=TRUE
After running the
controller set automatic_spare
command, use the
controller show automatic_spare
command again to verify that automatic spare has been enabled.
You can now replace a failed disk with a replacement disk, if
necessary.
Managing Flash EPROM Components
The CLI allows you to update the flash EPROM components of one
or more controllers. It can also be used to compare a controller’s
current flash contents to the flash images in a specified pair of user
!