Updating firmware for multiple servers – HP Integrated Lights-Out 4 User Manual
Page 191
5.
Click Apply.
Using the iLO Federation Management firmware update feature
The Group Firmware Update feature enables you to update the firmware of multiple servers from
a system running the iLO web interface.
A license is required if you want to make changes on the Group Firmware Update page. For more
information about iLO licensing, see the following website:
.
This feature allows you to do the following:
•
View the number of servers with each supported firmware version. The percentage of the total
number of servers with the listed firmware version is also displayed.
•
View the flash status for the grouped servers. The percentage of the total number of servers
with the listed flash status is also displayed.
•
View the TPM status for the grouped servers. The percentage of the total number of servers
with the listed TPM status is also displayed.
•
Update the firmware. The following firmware types are supported:
iLO
◦
◦
HP ProLiant System ROM
◦
System Programmable Logic Device
◦
SL Chassis Firmware
For more information, see
“Updating firmware for multiple servers” (page 191)
.
•
View the list of servers that will be affected by a firmware update. For more information, see
“Viewing affected systems” (page 193)
Updating firmware for multiple servers
1.
Download a supported type of firmware from the following website:
2.
Save the firmware file to a web server.
3.
Navigate to the iLO Federation
→Group Firmware Update page, as shown in
.
Using iLO Federation Management
191