Configuring serial cli options by using ilo rbsu – HP Integrated Lights-Out 4 User Manual
Page 135

Figure 64 Global iLO 4 Settings window
5.
For each option that you want to change, select the option, and press the spacebar to toggle
the setting to ENABLED or DISABLED. You can change the following settings:
•
iLO Functionality
•
iLO 4 ROM-Based Setup Utility
•
Require iLO 4 RBSU Login
•
Show iLO 4 IP during POST
•
Local Users
For more information about the first four options in the list, see
For more information about the last option in the list, see
“Configuring authentication and
directory server settings” (page 71)
6.
Press F10 to save the settings.
7.
Select File
→Exit to close iLO RBSU.
Configuring serial CLI options by using iLO RBSU
1.
Optional: If you access the server remotely, start an iLO remote console session.
You can use the .NET IRC or Java IRC.
2.
Restart or power on the server.
3.
Press F8 in the HP ProLiant POST screen.
4.
Select Settings
→CLI, and then press Enter.
5.
The Configure iLO Command-Line Interface menu opens, as shown in
Configuring iLO by using the ROM-based utilities
135