Configuring insight management integration – HP Integrated Lights-Out 4 User Manual
Page 116
Table 10 SNMP traps (continued)
Description
SNMP trap name
Memory errors have been corrected, but the memory module
should be replaced.
cpqHe5CorrMemReplaceMemModule 6064
The fault-tolerant power supply in the specified chassis and bay
reported AC power loss.
cpqHe4FltTolPowerSupplyACpowerloss 6069
The server power has been reset.
cpqSm2ServerReset 9001
The maximum unauthorized login attempt threshold has been
exceeded.
cpqSm2UnauthorizedLoginAttempts 9003
iLO 4 has detected a Self Test Error.
cpqSm2SelfTestError 9005
iLO 4 has detected that the security override jumper has been
toggled to the engaged position.
cpqSm2SecurityOverrideEngaged 9012
iLO 4 has detected that the security override jumper has been
toggled to the disengaged position.
cpqSm2SecurityOverrideDisengaged 9013
The server has been powered on.
cpqSm2ServerPowerOn 9017
The server has been powered off.
cpqSm2ServerPowerOff 9018
A request was made to power on the server, but the server could
not be powered on because of a failure condition.
cpqSm2ServerPowerOnFailure 9019
Generic trap. Verifies that the SNMP configuration, client SNMP
console, and network are operating correctly. You can use the
cpqHo2GenericTrap 11003
iLO web interface to generate this alert to verify receipt of the alert
on the SNMP console.
A power threshold has been exceeded.
cpqHo2PowerThresholdTrap 11018
A change in the health status of the server has occurred.
cpqHoMibHealthStatusArrayChangeTrap 11020
AMS detected a change in the status of an SAS or SATA physical
drive.
cpqSasPhyDrvStatusChange 5022
AMS detected a change in the status of an ATA disk drive.
cpqIdeAtaDiskStatusChange 14004
AMS detected that connectivity was restored to a logical network
adapter.
cpqNic3ConnectivityRestored 18011
AMS detected that the status of a logical network adapter changed
to Failed.
cpqNic3ConnectivityLost 18012
Configuring Insight Management integration
1.
Navigate to the Administration
→Management page.
2.
Click the SNMP Settings tab and scroll to the Insight Management Integration section, as
shown in
).
Figure 53 Editing the Insight Management Integration settings
3.
Configure the HP System Management Homepage (HP SMH) FQDN/IP Address.
This value sets the browser destination of the Insight Agent link on iLO pages.
116