HP Integrated Lights-Out 4 User Manual
Page 115
Table 10 SNMP traps
Description
SNMP trap name
SNMP has been initialized, the system has completed POST, or
AMS has started.
Cold Start Trap 0
SNMP has detected an authentication failure.
Authentication Failure Trap 4
A change has been detected in the status of the Smart Array
controller.
cpqDa6CntlrStatusChange 3033
A change has been detected in the status of a Smart Array logical
drive.
cpqDa6LogDrvStatusChange 3034
A change has been detected in the status of a Smart Array cache
module.
cpqDa6AccelStatusChange 3038
The Smart Array cache module has lost backup power.
cpqDa6AccelBadDataTrap 3039
The Smart Array cache module backup power has failed.
cpqDa6AccelBatteryFailed 3040
A change has been detected in the status of a Smart Array physical
drive.
cpqDa7PhyDrvStatusChange 3046
A change has been detected in the status of a Smart Array spare
drive.
cpqDa7SpareStatusChange 3047
A change has been detected in the SSD wear status of a Smart
Array physical drive.
cpqDaPhyDrvSSDWearStatusChange 3049
The server was shut down due to a thermal anomaly and is now
operational.
cpqHe3ThermalConfirmation 6026
One or more POST errors have occurred.
cpqHe3PostError 6027
The fault-tolerant power supplies have lost redundancy for the
specified chassis.
cpqHe3FltTolPowerRedundancyLost 6032
A fault-tolerant power supply has been inserted.
cpqHe3FltTolPowerSupplyInserted 6033
A fault-tolerant power supply has been removed.
cpqHe3FltTolPowerSupplyRemoved 6034
The fault-tolerant fan condition has been set to Degraded.
cpqHe3FltTolFanDegraded 6035
The fault-tolerant fan condition has been set to Failed.
cpqHe3FltTolFanFailed 6036
The fault-tolerant fans have lost redundancy.
cpqHe3FltTolFanRedundancyLost 6037
A fault-tolerant fan has been inserted.
cpqHe3FltTolFanInserted 6038
A fault-tolerant fan has been removed.
cpqHe3FltTolFanRemoved 6039
The temperature status has been set to Degraded, and the
temperature is outside the normal operating range. Depending
on the system configuration, this system might be shut down.
cpqHe3TemperatureDegraded 6041
The temperature status has been set to OK.
cpqHe3TemperatureOk 6042
The fault-tolerant power supply condition has been reset to OK.
cpqHe4FltTolPowerSupplyOk 6048
The fault-tolerant power supply condition has been set to Degraded.
cpqHe4FltTolPowerSupplyDegraded 6049
The fault-tolerant power supply condition has been set to Failed.
cpqHe4FltTolPowerSupplyFailed 6050
The Advanced Memory Protection subsystem has detected a
memory fault. Mirrored Memory has been activated.
cpqHeResilientMemMirroredMemoryEngaged 6051
The fault-tolerant power supplies have returned to a redundant
state.
cpqHe3FltTolPowerRedundancyRestore 6054
The fault-tolerant fans have returned to a redundant state.
cpqHe3FltTolFanRedundancyRestored 6055
Configuring iLO Management settings