beautypg.com

Brocade Virtual ADX MIB Reference (Supporting ADX v03.1.00) User Manual

Page 81

background image

Brocade Virtual ADX MIB Reference

69

53-1003312-01

Packet port information table

snPOSStatsInFrames
brcdIp.1.2.14.1.1.1.17
Syntax: Counter

Read only

The total number of packets received on the interface.

snPOSStatsOutFrames
brcdIp.1.2.14.1.1.1.18
Syntax: Counter

Read only

The total number of packets transmitted out of the interface.

snPOSStatsAlignErrors
brcdIp.1.2.14.1.1.1.19
Syntax: Counter

Read only

The number of packets that contained frame alignment errors.

snPOSStatsFCSErrors
brcdIp.1.2.14.1.1.1.20
Syntax: Counter

Read only

The number of packets that contained Frame Check Sequence
errors.

snPOSStatsFrameTooLong
s
brcdIp.1.2.14.1.1.1.21
Syntax: Counter

Read only

The number of packets that were longer than the configured MTU.

snPOSStatsFrameTooShort
s
brcdIp.1.2.14.1.1.1.22
Syntax: Counter

Read only

The number of packets that were shorter than the minimum valid
length.

snPOSStatsInDiscard
brcdIp.1.2.14.1.1.1.23
Syntax: Counter

Read only

The number of inbound packets that were discarded to prevent
them from being delivered to a higher-layer protocol, even though
no errors had been detected. For example, a packet may be
discarded to free up buffer space.

snPOSStatsOutDiscard
brcdIp.1.2.14.1.1.1.24
Syntax: Counter

Read only

The number of outbound packets that were discarded to prevent
them from being transmitted, even though they contain no errors.
For example, a packet may be discarded to free up buffer space.

snPOSInOctets
brcdIp.1.2.14.1.1.1.25
Syntax: OctetString

Read only

The total number of packets in octets that were received on the
interface, including framing characters.
This object is a 64-bit counter of the ifInOctets object, defined in
RFC 1213. The octet string is in big-endian byte order.

snPOSOutOctets
brcdIp.1.2.14.1.1.1.26
Syntax: OctetString

Read only

The total number of packets in octets that were transmitted out of
the interface, including framing characters.
This object is a 64-bit counter of the ifOutOctets object, defined in
RFC 1213. The octet string is in big-endian byte order.

snPOSStatsInBitsPerSec
brcdIp.1.2.14.1.1.1.27
Syntax: Gauge

Read only

The number of bits per second received on the interface over a
five-minute interval.

snPOSStatsOutBitsPerSec
brcdIp.1.2.14.1.1.1.28
Syntax: Gauge

Read only

The number of bits per second transmitted out of the interface over
a five-minute interval.

snPOSStatsInPktsPerSec
brcdIp.1.2.14.1.1.1.29
Syntax: Gauge

Read only

The number of packets per second received on the interface over a
five-minute interval.

snPOSStatsOutPktsPerSec
brcdIp.1.2.14.1.1.1.30
Syntax: Gauge

Read only

The number of packets per second transmitted out of the interface
over a five minute interval.

Name, OID, and Syntax

Access

Description