Packet port information table
snPOSStatsInFrames
brcdIp.1.2.14.1.1.1.17
Syntax: Counter
Read only
The total number of packets received on the interface.
snPOSStatsOutFrames
brcdIp.1.2.14.1.1.1.18
Syntax: Counter
Read only
The total number of packets transmitted out of the interface.
snPOSStatsAlignErrors
brcdIp.1.2.14.1.1.1.19
Syntax: Counter
Read only
The number of packets that contained frame alignment errors.
snPOSStatsFCSErrors
brcdIp.1.2.14.1.1.1.20
Syntax: Counter
Read only
The number of packets that contained Frame Check Sequence
errors.
snPOSStatsFrameTooLong
s
brcdIp.1.2.14.1.1.1.21
Syntax: Counter
Read only
The number of packets that were longer than the configured MTU.
snPOSStatsFrameTooShort
s
brcdIp.1.2.14.1.1.1.22
Syntax: Counter
Read only
The number of packets that were shorter than the minimum valid
length.
snPOSStatsInDiscard
brcdIp.1.2.14.1.1.1.23
Syntax: Counter
Read only
The number of inbound packets that were discarded to prevent
them from being delivered to a higher-layer protocol, even though
no errors had been detected. For example, a packet may be
discarded to free up buffer space.
snPOSStatsOutDiscard
brcdIp.1.2.14.1.1.1.24
Syntax: Counter
Read only
The number of outbound packets that were discarded to prevent
them from being transmitted, even though they contain no errors.
For example, a packet may be discarded to free up buffer space.
snPOSInOctets
brcdIp.1.2.14.1.1.1.25
Syntax: OctetString
Read only
The total number of packets in octets that were received on the
interface, including framing characters.
This object is a 64-bit counter of the ifInOctets object, defined in
RFC 1213. The octet string is in big-endian byte order.
snPOSOutOctets
brcdIp.1.2.14.1.1.1.26
Syntax: OctetString
Read only
The total number of packets in octets that were transmitted out of
the interface, including framing characters.
This object is a 64-bit counter of the ifOutOctets object, defined in
RFC 1213. The octet string is in big-endian byte order.
snPOSStatsInBitsPerSec
brcdIp.1.2.14.1.1.1.27
Syntax: Gauge
Read only
The number of bits per second received on the interface over a
five-minute interval.
snPOSStatsOutBitsPerSec
brcdIp.1.2.14.1.1.1.28
Syntax: Gauge
Read only
The number of bits per second transmitted out of the interface over
a five-minute interval.
snPOSStatsInPktsPerSec
brcdIp.1.2.14.1.1.1.29
Syntax: Gauge
Read only
The number of packets per second received on the interface over a
five-minute interval.
snPOSStatsOutPktsPerSec
brcdIp.1.2.14.1.1.1.30
Syntax: Gauge
Read only
The number of packets per second transmitted out of the interface
over a five minute interval.
Name, OID, and Syntax