beautypg.com

Brocade Virtual ADX MIB Reference (Supporting ADX v03.1.00) User Manual

Page 36

background image

24

Brocade Virtual ADX MIB Reference

53-1003312-01

Software configuration

snVLanGroupSetAllVLan
brcdIp.1.1.3.1.7
Syntax: Integer32

Read-write Shows the VLanIndex of a particular entry in snVLanByPortTable

(snVLanByPortVLanIndex). All the attributes of the row except for
PortMask will be used to set the same attributes for the entire VLAN
group. VLanId and PortMask must be set for the particular entry prior
to setting this object. Switch software will be based on this VLAN
information to set the entire VLAN.
NOTE: All the intended attributes of the given row of the table (given

VLAN) must be set prior setting this object. When this object is
set, Set-All-VLAN action takes place simultaneously. The
previous setting is overwritten by the new one.

snSwPortSetAll
brcdIp.1.1.3.1.8
Syntax: Integer32

Read-write The value of this object is the index number of the snSwPortInfoTable

(snSwPortInfoPortIndex). snSwPortInfoMonitorMode,
snSwPortInfoTagType, snSwPortInfoChnMode, snSwPortInfoSpeed,
snSwPortInfoAdminStatus are all the read-write attributes of that row
of table. They will be used to set the same attributes for all the ports in
the system.
NOTE: Before setting this object, all the intended attributes of the

given row of the table must be set. Otherwise, the current data
of the row will be used to set the entire port-table. The
previous setting will be overwritten by the new one.

snFdbTableCurEntry
brcdIp.1.1.3.1.9
Syntax: Integer32

Read only

Shows the total number of entries in the Filtering Databse (FDB) that
are configured currently.

snFdbTableStationFlush
brcdIp.1.1.3.1.10
Syntax: Integer

Read-write Shows the state of the flush operation for the FDB table.

The following value can be written:

flush(3) – Perform the flush operation. Once the flush operation
starts, any new flush requests will be rejected until the operation
is complete or failed.

The following values can only be read:

normal(1) – Normal state

error(2) – Operation failed

flushing(4) – Operation is in process

snPortStpSetAll
brcdIp.1.1.3.1.11
Syntax: Integer32

Read-write The value of this object is 1, which means that Port STP Set-all

command is invoked. The snPortStpPriority and, snPortStpPathCost,
which are the read-write STP related attributes of the first row of table,
will be used to set the same attributes for all the ports in the system.
NOTE: Before setting this object, all the intended attributes of the

given row of the table must be set. Otherwise, the current data
of the row will be used to set the entire port-table. The
previous setting will be overwritten by the new one.

snSwProbePortNum
brcdIp.1.1.3.1.12
Syntax: Integer32

Read-write Indicates which chassis port is assigned as the chassis switch probe

port. That port operates as a traffic analyzer port. Only one port in the
chassis or stackable switch can be assigned as the traffic analyzer
port. The value of this object represents the following:

Bit 0 to bit 7 – Port number

Bit 8 to bit 11 – Slot number

snSw8021qTagMode
brcdIp.1.1.3.1.13
Syntax: Integer

Read-write Indicates whether or not IEEE802.1q has been enabled for the switch

group.

disabled(0)

enabled(1)

Default: disabled(0)

Name, OID, and Syntax

Access