beautypg.com

Brocade Virtual ADX MIB Reference (Supporting ADX v03.1.00) User Manual

Page 152

background image

140

Brocade Virtual ADX MIB Reference

53-1003312-01

OSPF interface configuration tables

snOspfIfPort
brcdIp.1.2.4.4.1.1.1
Syntax: Integer32

Read only

The physical router port of this OSPF interface.

snOspfIfAreaId
brcdIp.1.2.4.4.1.1.2
Syntax: AreaID

Read-write

Specifies the address of the area in a 32-bit integer. This
address uniquely identifies the area to which the interface
connects. Area ID 0.0.0.0 is used for the OSPF backbone.
Default:’00000000’h, which equals to 0.0.0.0

snOspfIfAdminStat
brcdIp.1.2.4.4.1.1.3
Syntax: Integer

Read-write

Indicates if neighbor relationships may be formed on this
interface:

disabled(0) – The interface is external to OSPF

enabled(1) – Neighbor relationships may be formed on
the interface, which will be advertised as an internal
route to an area.

Default: enabled(1)

snOspfIfRtrPriority
brcdIp.1.2.4.4.1.1.4
Syntax: DesignatedRouterPriority

Read-write

Specifies the priority of this interface. This object is used in the
designated router election algorithm for multi-access
networks.
Valid values: 0 – 255. A value of 0 signifies that the router is
not eligible to become the designated router on this particular
network.
If two or more routers have the same priority value, then the
router with the highest router ID becomes the designated
router. The router with the next highest router ID becomes the
backup designated router.

snOspfIfTransitDelay
brcdIp.1.2.4.4.1.1.5
Syntax: UpToMaxAge

Read-write

Shows the time it takes to transmit link-state update packets
on this interface.
Valid values: 0 – 3600 seconds
Default: 1 second

snOspfIfRetransInterval
brcdIp.1.2.4.4.1.1.6
Syntax: UpToMaxAge

Read-write

Specifies the number of seconds between link-state
advertisement retransmissions, for adjacencies belonging to
this interface. This value is also used when retransmitting
database description and link-state request packets. Values
can be from 0 – 3600 seconds.
Default: 5 seconds

snOspfIfHelloInterval
brcdIp.1.2.4.4.1.1.7
Syntax: HelloRange

Read-write

Specifies the number of seconds that router waits before it
sends the next Hello packet on this interface. This value must
be the same for all routers attached to a common network.
Values can be from 1 – 65535 seconds (up to ‘FFFF’h).
Valid values: 1 – 65535 seconds
Default: 10 seconds

snOspfIfRtrDeadInterval
brcdIp.1.2.4.4.1.1.8
Syntax: PositiveInteger

Read-write

Specifies the number of seconds that neighbor routers wait for
a router’s Hello packets before they declare that the router is
down. This should be a multiple of the Hello interval. This
value must be the same for all routers attached to a common
network.
Valid values: 1 – 2147483647 seconds
Default: 40 seconds

Name, OID, and Syntax

Access

Description