26
Brocade Virtual ADX MIB Reference
53-1003312-01
Software configuration
The following objects are not supported on the ServerIron products.
snSwProtocolVLanMode
brcdIp.1.1.3.1.31
Syntax: Integer
Read-write Indicates whether or not protocol VLAN is enabled.
•
disabled(0)
•
enabled(1)
snMacStationVLanId
brcdIp.1.1.3.1.32
Syntax: Integer
Read-write Shows the MAC Station’s VLAN ID index in the standard Forwarding
Database for Transparent Bridge Table. (dot1dTpFdbTable). Since the
dot1dTpFdbTable index is the MAC Address assigned to one of the
ports in the bridge (VLAN) and each MAC address can be re-assigned
to different ports belonging to different bridges (VLANs), the
snMacStationVLanId can be used to specify which bridge (VLAN) MAC
Station information of the dot1dTpFdbTable to retrieve. If you do not
specify the VLAN ID in this MIB, the default VLAN (bridge) ID will be
used when dot1dTpFdbTable is retrieved.
Valid values: 1 – 4095
snSwClearCounters
brcdIp.1.1.3.1.33
Syntax: Integer
Read-write Clears software counters:
•
valid(0) – an SNMP-GET of this MIB shows that it is valid
command to use.
•
clear(1) – Clear counter command of the following counters:
Dot3, MIB2, IP and IPX counters for all ports.
snSw8021qTagType
brcdIp.1.1.3.1.34
Syntax: Integer32
Read-write Specifies the IEEE802.1q tag type that is embedded in the
length/type field of an Ethernet packet. It specifies that the two octets
after the length/type field in an Ethernet packet are the tag value.
Default: 33024
snSwBroadcastLimit
brcdIp.1.1.3.1.35
Syntax: Integer32
Read-write Specifies the number of broadcast packets per second. This limits the
number of broadcast packets to forward out of the switch ports.
Setting this object to 0 disables the limitation check.
Default: 0
snSwMaxMacFilterPerSyste
m
brcdIp.1.1.3.1.36
Syntax: Integer
Read only
Specifies the maximum number of MAC Filters per system in the MAC
Filter table.
snSwMaxMacFilterPerPort
brcdIp.1.1.3.1.37
Syntax: Integer
Read only
Specifies the maximum number of MAC Filters per port in the Port
MAC Access Filter table.
snSwDefaultVLanId
brcdIp.1.1.3.1.38
Syntax: Integer
Read-write Shows the VLAN ID of the default port VLAN.
Valid values: 1 – 4095
snSwGlobalAutoNegotiate
brcdIp.1.1.3.1.39
Syntax: Integer
Read-write Applies only to Gigabit Ethernet ports.
Specifies the negotiation mode of the port:
•
disable(0) – All Gigabit Ethernet ports are in non- negotiation
mode.
•
enable(1) – All Gigabit Ethernet ports will start auto-negotiation
indefinitely until they succeed.
•
negFullAuto(2) – All Gigabit Ethernet ports will start with
auto-negotiation. If the negotiation fails, then they will
automatically switch to non-negotiation mode. Gigabit Ethernet
ports on all stackable products except for TurboIron/8 do not
support negFullAuto(2).
•
other(3)
Default: negFullAuto(2)
Name, OID, and Syntax
Access
Description