beautypg.com

Bgp traps, Port security traps, Snmp traps for rsvp-signaled lsp state – Brocade Virtual ADX MIB Reference (Supporting ADX v03.1.00) User Manual

Page 279: Bgp traps port security traps

background image

Brocade Virtual ADX MIB Reference

267

53-1003312-01

Virtual ADX traps

BGP traps

Port security traps

The Port Security feature enables a device to learn a limited number of “secure” MAC addresses on
an interface. The interface will forward only those packets with source MAC addresses that match
these secure addresses. If the interface receives MAC addresses that are included in its secure
MAC list, the device generates the following traps:

NOTE

This trap applies to ports that have the Port Security feature enabled.

SNMP traps for RSVP-signaled LSP state

SNMP traps that identify when an RSVP-Signaled LSP goes up and down and also when an LSP
switches traffic to a new active path.

Trap Name and Number

Varbinds

Severity

Description and Trap Message

snTrapBgpPeerUp
brcdIp.0.65

snAgGblTrapMessage

Informational

The BGP peer is up.
Trap Message:
BGP Peer UP(ESTABLISHED)

snTrapBgpPeerDown
brcdIp.0.66

snAgGblTrapMessage

Informational

The BGP peer is down.
Trap Message:
BGP Peer DOWN

()\n

Trap Name and Number

Varbinds

Severity

Description and Trap Message

snTrapPortSecurityViolation
brcdIp.0.77

snAgGblTrapMessage Minor

Packets from unknown MAC address are
dropped.
Sample Trap Message:

Brocade Trap: Port

Security Violation

snTrapPortSecurityShutdow
n
brcdIp.0.78

snAgGblTrapMessage Minor

The port is disabled for the amount of time
configured using the violation shutdown
port security CLI command.
Sample Trap Message:

Brocade Trap: Port

Security Violation Cause

Shutdown

Trap Name and Number

Varbinds

Severity

System Message Format

snMplsLspUp
brcdIp.0.139

mplsLspName
mplsLspPathN
ame

Informational

Informs that the specified RSVP-signaled LSP
using the specified active path is up.