beautypg.com

Snapshot mode, Manual trigger mode, Any trigger in pattern mode – Teledyne LeCroy Sierra M124 User Manual User Manual

Page 76

background image

Teledyne LeCroy

SAS/SATA Software Menus and Toolbars

74

 

 

Sierra M124 SAS/SATA Protocol Analyzer User Manual

Starting a data capture with Pattern selected triggers when specific pattern(s) are 
detected in the captured data stream. The following three ways can trigger the analyzer 
with Pattern selected.

Trigger on any pattern (Any Trigger Mode)

External Trigger

Trigger on a sequence of patterns (Sequential Trigger Mode)

Snapshot Mode

To trigger immediately on any pattern, check the Don’t care (Snapshot) button.

Figure 2.36: Default Trigger Selected

Manual Trigger Mode

To perform a manual trigger, check the Manual Trig radio button. In the Manual Trigger 
mode, the analyzer captures bus traffic continually from when you use the Manual 
Trigger until you click the Stop Recording button (on the analyzer toolbar), which triggers 

the analyzer. Clicking the Manual Trigger 

 button on the application toolbar creates a 

Trigger Event and uploads the trace with the specified trigger position.

Any Trigger in Pattern Mode

In Pattern mode, the Analyzer triggers whenever any of the patterns selected for 
triggering occurs (an OR condition). The procedure for selecting trigger parameters is 
identical to that for selecting capture parameters. All items selected for triggering appear 
in the Project Tree.

To define patterns for triggering, check the Pattern button in the Trigger dialog (see 

Figure 2.37 on page 75

.)