beautypg.com

20 multi - link triggering, 21 set timers – Teledyne LeCroy Sierra M124 User Manual User Manual

Page 110

background image

Teledyne LeCroy

SAS/SATA Software Menus and Toolbars

108

 

 

Sierra M124 SAS/SATA Protocol Analyzer User Manual

Figure 2.79: SAS: Choosing a Pattern

6. Choose pattern(s) and click the +>> button to add them for capture or exclusion. You 

define each pattern the same way as in Easy mode (see 

“Defining Patterns” on 

page 62

).

7. For an output trigger, click the down arrow in the Ext. Out field and choose an 

output trigger level. Note: Do not use the LOW setting in Advanced Mode.

8. To go to another state, click the down arrow in the Go To field and select a state. If 

no other state has been defined, choose New State to add a state.

2.2.20

Multi - Link Triggering

You can set different triggering for each link. To set different trigger conditions for a link, 
check the Multi Sequencer check box and select the link for setup from the Port drop‐
down list. Clicking the Make Same as Current button displays a warning: all sequencers 
will be changed to have same states as current sequencer. Click Yes to do so.

Figure 2.80: SAS: Multi - Link Triggering Setup

2.2.21

Set Timers

You can set and use up to three timers for triggering. You can set each timer for each 
state, or set it to continue from one set in the previous state. The timer defined for a 
particular state starts when the system enters that state. You can set a timer for any IF or 
ELSE IF condition. To set up the timers, click the ellipses in the Timer field next to the IF or 
ELSE IF condition in each state and define each of the timers in the Set Timers dialog (see 

Figure 2.81 on page 109

).