beautypg.com

Ata command report, Atapi report – Teledyne LeCroy Sierra M124 User Manual User Manual

Page 134

background image

Teledyne LeCroy

Analysis

132

 

 

Sierra M124 SAS/SATA Protocol Analyzer User Manual

ATA Command Report

To display the ATA Command Report, click the ATA Command tab. The ATA Command 
Report displays information in the following columns:

Command: All, Custom, Check Power Mode, Execute Device Diagnostic, 
Flush Cache, Identify Device, Read DMA Ext, Read FPDMA Queue, Set Feature, 
Write DMA Ext, Write FPDMA Queue

PM Port

Direction: All, H‐>D, D‐>H, I‐>T, T‐>I, or Custom

Number of FIS: All, Custom, or a number

Payload Size: All, Custom, or a number of DWORDs

Status: All, Custom, Incomplete, Normal Output

Timeout: such as All, Custom, N/A, Yes, No (see 

“Time out of ATA Command 

Report” on page 132

)

Duration: All, Custom, or time unit

Count: All, Custom, or a number of occurrences

%: of total count

Figure 3.29: SATA: ATA Command Report

Time out of ATA Command Report

The Time out shows the NCQ time out. It is applicable for only NCQ commands. A 
threshold can be set in the "NCQ commands Timeout Threshold", the default value is 
1000 sec (the user can change it to any value). The statistical report provides a "Time 
out" report based on this threshold. Any NCQ command that takes more than the given 
threshold is flagged as "yes", which means that a timeout occurred for that command.

ATAPI Report

To display the ATAPI Report (see 

Figure 3.30 on page 133

), click the ATAPI tab. The ATAPI 

Report displays information in the following columns:

Command: All, Custom, Inquiry, Mode Sense 10, Read10, Request Sense

Direction: All, H‐>D, D‐>H, or Custom

Number of FIS or Number of Transport: All, Custom, or a number

Payload Size: All, Custom, or a number of DWORDs

Status: All, Custom, Check Condition, Good

Duration: All, Custom, or time unit (accumulative)

Count: All, Custom, or a number of occurrences

%: of total count