Sierra M124 SAS/SATA Protocol Analyzer User Manual
243
Scenario Actions
Teledyne LeCroy
TABLE 4.3: Test State Actions
Action
Description
Analyzer
Trigger
The Jammer sends a trigger to the Analyzer.
Beep
Emits audible sound of duration selectable via
drop‐down list.
Capture Data DWORD
Captures a data DWORD into one of four registers.
Inject
CRC Error
Injects a CRC error into the line.
Invalid 10bit‐code
Error
Injects invalid 10b code into the line.
Running Disparity
Error
Injects a Running Disparity (RD) error into traffic.
Insert
Address Frame
FIS Frame
SAS Primitive
SATA Primitive
SMP Frame
SSP Frame
Inserts a frame or primitive.
Insert DWORD
Inserts DWORD.
Link
Disconnect
Puts both InFusion SAS ports at electrical idle
immediately. This action is only in effect while the
scenario is running, and the Jammer will
reconnect the line when the scenario is stopped.
Reconnect
Starts traffic pass‐through immediately. This
action restarts traffic after a previous disconnect
command. Once traffic is passing through, the
initiator and target resume OOB signaling.
Monitor/Count
Opens a window to count the number of events
that occur during a session. A session is a time
interval during which a scenario runs.
Remove
Frame Partially
Primitive
Whole Frame
Removes the targeted event from the traffic.In
InFusion.
A Remove primitive action is implemented by
replacing the primitive with an idle data DWORD.
A Remove frame action is implemented by
replacing the start‐of‐frame and end‐of‐frame
primitives with an idle data DWORD.
Restart
All Sequences
1
Restart all sequences in the scenario.
1
Current Sequence
1
Restart the sequence that contains this action
definition.
1
SNW
Speed Negotiation
Retime
Set RCDT, SNTT, ALT/TLT, TX speed, TRAIN/
TRAIN_DONE pattern, and/or PHY Capability.
Speed Negotiation
Violation
Set Violation Type.