beautypg.com

4 launch jammer, 5 launch trainer, 6 crosssync control panel – Teledyne LeCroy Sierra M124 User Manual User Manual

Page 51

background image

    

Sierra M124 SAS/SATA Protocol Analyzer User Manual

49

SAS/SATA Software Menus and Toolbars

  Teledyne LeCroy

The results display shows each transaction for every layer identified in a different color 
and the data direction identified with data direction arrows. Upstream traffic has an 
arrow from right to left:. Downstream traffic has an arrow left to right: .

Layers can be hidden by clicking the corresponding Show/Hide button on the menu bar. 
The system retains all captured data, but the display has fewer data layers for simpler 
viewing.

You can configure the viewer display for test and viewing preferences (see 

“Viewer 

Display” on page 115

 for details about configuring the viewer display).

The Analysis Project dialog offers you a comprehensive set of choices to create a trigger 
and capture project satisfying some specific need. You can set the Analyzer to:

Capture specific patterns (see 

“Patterns and Data Capture Setup” on page 59

).

Capture different patterns pre‐ and post‐trigger.

Exclude parameters from capture.

Trigger on a pattern or sequence of patterns (see 

"Trigger Setup" on page 73

).

Configure trace capture memory (Settings tab).

Select file to save trace capture in memory (Settings tab).

Include a project note (Notes tab).

2.2.4

Launch Jammer

The Launch Jammer option invokes InFusion. For more information refer to 

“InFusion 

Overview” on page 221

.

2.2.5

Launch Trainer

The Launch Trainer option invokes Trainer. For more information refer to 

“Sierra Trainer 

Traffic Generation” on page 277

.

2.2.6

CrossSync Control Panel

The CrossSync Control Panel allows you to select analyzers for synchronization and 
manage the recording process. It supports a wide combination of Teledyne LeCroy’s 
flagship analyzers including PCI Express, USB, DDR, Serial ATA (SATA), Serial Attached SCSI 
(SAS), Fibre Channel (FC) and Ethernet.

CrossSync is Teledyne LeCroy’s analyzer synchronization solution that enables time‐
aligned display of protocol traffic from multiple daisy‐chained analyzers showing packet 
traffic from multiple high‐speed serial busses. A lightweight software control panel allows 
users to select analyzers for synchronization and manage the recording process. Captured 
traffic is displayed using the latest Protocol Suite software (in separate windows) with all 
the protocol specific search and reporting features.

Captured packets are displayed in separate windows that share a common time scale. 
Navigating the traffic in either direction will scroll to the same timestamp in a 
synchronized window. When using the CrossSync option, users can access the full 
complement of analysis capabilities available within the individual Teledyne LeCroy 
software. Search, reporting, and decoding all operate normally.