3 firmware update procedure – Comtech EF Data CDM-625 User Manual
Page 93

CDM-625 Advanced Satellite Modem
Revision 15
Updating Firmware
MN-CDM625
4–3
4.3 Firmware Update Procedure
4.3.1 Getting Started: Preparing for the Firmware Download
Step Task
1
Connect the Windows-based user PC to the CDM-625:
•
Connect the appropriate modem Ethernet port either via a hub or a switch or directly with an Ethernet or
crossover cable. Make sure that a compatible web browser is running on the PC.
•
Connect the modem “Remote Control” port to a serial port on the PC. Make sure that a terminal emulator
program such as Hyper Terminal is running on the PC.
2
Identify the CDM-625 configuration in use, and its firmware number and current version:
A. For the CDM-625 Base Modem
, the firmware number and running version can be obtained as follows:
•
From the modem front panel – The firmware version is available from the VFD’s top-level “splash” screen. To
view this screen, press the [CLEAR] key several times.
The firmware numbers are provided within the SELECT: UTIL Firmware Info Image#1 or
Image#2 menu screens. For more information, see Chapter 5. FRONT PANEL OPERATION.
•
From HTTP via the Base Modem Web Server Interface – The Bootrom, Bulk1 and Bulk2 firmware loads may
be viewed on the Admin | Firmware | Base Modem page. For more information, see Chapter 6.5. Web
Server (HTTP) Interface.
•
Using serial Remote Control query – The firmware number, versions, and revision level can be queried as
follows:
o The condensed query displays the firmware version – Type <0/SWR?
o The detailed query displays the complete firmware load information – Type <0/FRW?1 (for Image 1) or
<0/FRW?2 (for Image 2)
For more information, see Appendix D. SERIAL REMOTE CONTROL.
B. For the CDM-625 with installed IP Packet Processor
, the firmware number and running version can be
obtained as follows:
•
From the modem front panel – Select the Utilities: Firmware Packet-Processor Info Image#1 or
Image#2 menu trees. For more information, see Chapter 5. FRONT PANEL OPERATION.
•
From HTTP via the Base Modem Web Server Interface – Select the Admin | Firmware | Packet Processor
page. The Bootrom, Bulk1 and Bulk2 firmware loads may be viewed here. For more information, see Chapter 6.5
Web Server (HTTP) Interface.
•
Using serial Remote Control query – Use the IP Packet Processor’s firmware revision query <0/VS1? (Image
1) or <0/VS2? (Image 2).
For more information, see Appendix D. REMOTE CONTROL.