3 firmware update procedure – Comtech EF Data CDM-625 User Manual

Page 93

background image

CDM-625 Advanced Satellite Modem

Revision 15

Updating Firmware

MN-CDM625

4–3

4.3 Firmware Update Procedure

4.3.1 Getting Started: Preparing for the Firmware Download

Step Task

1

Connect the Windows-based user PC to the CDM-625:

Connect the appropriate modem Ethernet port either via a hub or a switch or directly with an Ethernet or

crossover cable. Make sure that a compatible web browser is running on the PC.

Connect the modem “Remote Control” port to a serial port on the PC. Make sure that a terminal emulator

program such as Hyper Terminal is running on the PC.

2

Identify the CDM-625 configuration in use, and its firmware number and current version:

A. For the CDM-625 Base Modem

, the firmware number and running version can be obtained as follows:

From the modem front panel – The firmware version is available from the VFD’s top-level “splash” screen. To

view this screen, press the [CLEAR] key several times.

The firmware numbers are provided within the SELECT: UTIL Firmware Info Image#1 or

Image#2 menu screens. For more information, see Chapter 5. FRONT PANEL OPERATION.

From HTTP via the Base Modem Web Server Interface – The Bootrom, Bulk1 and Bulk2 firmware loads may

be viewed on the Admin | Firmware | Base Modem page. For more information, see Chapter 6.5. Web

Server (HTTP) Interface.

Using serial Remote Control query – The firmware number, versions, and revision level can be queried as

follows:

o The condensed query displays the firmware version – Type <0/SWR?

o The detailed query displays the complete firmware load information – Type <0/FRW?1 (for Image 1) or

<0/FRW?2 (for Image 2)

For more information, see Appendix D. SERIAL REMOTE CONTROL.

B. For the CDM-625 with installed IP Packet Processor

, the firmware number and running version can be

obtained as follows:

From the modem front panel – Select the Utilities: Firmware Packet-Processor Info Image#1 or

Image#2 menu trees. For more information, see Chapter 5. FRONT PANEL OPERATION.

From HTTP via the Base Modem Web Server Interface – Select the Admin | Firmware | Packet Processor

page. The Bootrom, Bulk1 and Bulk2 firmware loads may be viewed here. For more information, see Chapter 6.5

Web Server (HTTP) Interface.

Using serial Remote Control query – Use the IP Packet Processor’s firmware revision query <0/VS1? (Image

1) or <0/VS2? (Image 2).

For more information, see Appendix D. REMOTE CONTROL.