D.5.8 buc parameters (l-band device) – Comtech EF Data CDM-625 User Manual
Page 521

CDM-625 Advanced Satellite Modem
Revision 15
Appendix D
MN-CDM625
D–57
D.5.8
BUC Parameters (L-Band Device)
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to
Query
BUC
Power Supply
enable
BPS=
Exception –
600L Emulation:
ODP=
1 byte, value
of 0 or 1
Command or Query.
BUC Power Supply control in the form x. where:
0 = Disable the BUC DC Power Supply
1 = Enable the BUC DC Power Supply
BPS=
BPS?
BPS*
BPS#
BPS?
Exception –
600L Emulation:
ODP?
BPS=x
(see Description of
Arguments)
BUC
10 MHz
Reference
BFR=
Exception –
600L Emulation:
ODR=
1 byte
Command or Query.
In the form x, where:
0 = OFF
1 = ON
BFR=
BFR?
BFR*
BFR#
BFR?
Exception –
600L Emulation:
ODR?
BFR=x
(see Description of
Arguments)
BUC
Current
Low Limit
BCL=
Exception –
600L Emulation:
ODL=
4 bytes
Command or Query.
BUC Current Low Limit, in the form xxxx, where xxxx is a value between 0 and 4000mA, in 100mA
increments.
BCL=
BCL?
BCL*
BCL#
BCL?
Exception –
600L Emulation:
ODL?
BCL=xxxx
(see Description of
Arguments)
BUC
Current
High Limit
BCH=
Exception –
600L Emulation:
ODH=
4 bytes
Command or Query.
BUC Current High Limit, in the form xxxx, where xxxx is a value between 0 and 4000mA, in 100mA
increments.
BCH=
BCH?
BCH*
BCH#
BCH?
Exception –
600L Emulation:
ODH?
BCH=xxxx
(see Description of
Arguments)
BUC
Address
BAD=
Exception –
600L Emulation:
OAD=
1 byte, value
of 1 to 15
Command or Query.
BUC Address, in the form xx, where xx is a value between 1 and 15.
Note: This command is only valid when the FSK is enabled.
BAD=
BAD?
BAD*
BAD#
BAD?
Exception –
600L Emulation:
OAD?
BAD=xx
(see Description of
Arguments)
BUC
Output Power
Enable
BOE=
Exception –
600L Emulation:
OOP=
1 byte, value
of 0 or 1
Command or Query.
BUC Tx Carrier Output Power Enable in the form x, where:
0 = OFF
1 = ON
Note: This command is only valid when the FSK is enabled.
BOE=
BOE?
BOE*
BOE#
BOE?
Exception –
600L Emulation:
OOP?
BOE=x
(see Description of
Arguments)
BUC
DC
Current
N/A
4 bytes
Query only.
BUC DC current, in the form xxxx, where xxxx is a value between 0 and 9999, units mA.
If not available, response is 0000.
N/A
BDC?
Exception –
600L Emulation:
ODC?
BDC=xxxx
(see Description of
Arguments)
BUC
Voltage
N/A
4 bytes
Query only.
BUC Voltage, in the form xx.x, where xx.x is a value between 0 and 64.0, units in volts.
N/A
BDV?
Exception –
600L Emulation:
ODV?
BDV=xx.x
(see Description of
Arguments)
BUC
Output Power
Level
N/A
4 bytes
Query only.
BUC Output Power Level, in the form xx.x, where xx.x is the value in dBm.
Returns xxxx when FSK is not enabled.
Example: BOL=37.4
N/A
BOL?
Exception –
600L Emulation:
OOL?
BOL=xx.x
(see Description of
Arguments)