CDM-625 Advanced Satellite Modem

Revision 15

Appendix D

MN-CDM625

D–57

D.5.8

BUC Parameters (L-Band Device)

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to

Query

BUC

Power Supply

enable

BPS=

Exception –

600L Emulation:

ODP=

1 byte, value

of 0 or 1

Command or Query.

BUC Power Supply control in the form x. where:

0 = Disable the BUC DC Power Supply

1 = Enable the BUC DC Power Supply

BPS=

BPS?

BPS*

BPS#

BPS?

Exception –

600L Emulation:

ODP?

BPS=x

(see Description of

Arguments)

BUC

10 MHz

Reference

BFR=

Exception –

600L Emulation:

ODR=

1 byte

Command or Query.

In the form x, where:

0 = OFF

1 = ON

BFR=

BFR?

BFR*

BFR#

BFR?

Exception –

600L Emulation:

ODR?

BFR=x

(see Description of

Arguments)

BUC

Current

Low Limit

BCL=

Exception –

600L Emulation:

ODL=

4 bytes

Command or Query.

BUC Current Low Limit, in the form xxxx, where xxxx is a value between 0 and 4000mA, in 100mA

increments.

BCL=

BCL?

BCL*

BCL#

BCL?

Exception –

600L Emulation:

ODL?

BCL=xxxx

(see Description of

Arguments)

BUC

Current

High Limit

BCH=

Exception –

600L Emulation:

ODH=

4 bytes

Command or Query.

BUC Current High Limit, in the form xxxx, where xxxx is a value between 0 and 4000mA, in 100mA

increments.

BCH=

BCH?

BCH*

BCH#

BCH?

Exception –

600L Emulation:

ODH?

BCH=xxxx

(see Description of

Arguments)

BUC

Address

BAD=

Exception –

600L Emulation:

OAD=

1 byte, value

of 1 to 15

Command or Query.

BUC Address, in the form xx, where xx is a value between 1 and 15.
Note: This command is only valid when the FSK is enabled.

BAD=

BAD?

BAD*

BAD#

BAD?

Exception –

600L Emulation:

OAD?

BAD=xx

(see Description of

Arguments)

BUC

Output Power

Enable

BOE=

Exception –

600L Emulation:

OOP=

1 byte, value

of 0 or 1

Command or Query.

BUC Tx Carrier Output Power Enable in the form x, where:

0 = OFF

1 = ON

Note: This command is only valid when the FSK is enabled.

BOE=

BOE?

BOE*

BOE#

BOE?

Exception –

600L Emulation:

OOP?

BOE=x

(see Description of

Arguments)

BUC

DC

Current

N/A

4 bytes

Query only.

BUC DC current, in the form xxxx, where xxxx is a value between 0 and 9999, units mA.

If not available, response is 0000.

N/A

BDC?

Exception –

600L Emulation:

ODC?

BDC=xxxx

(see Description of

Arguments)

BUC

Voltage

N/A

4 bytes

Query only.

BUC Voltage, in the form xx.x, where xx.x is a value between 0 and 64.0, units in volts.

N/A

BDV?

Exception –

600L Emulation:

ODV?

BDV=xx.x

(see Description of

Arguments)

BUC

Output Power

Level

N/A

4 bytes

Query only.

BUC Output Power Level, in the form xx.x, where xx.x is the value in dBm.

Returns xxxx when FSK is not enabled.
Example: BOL=37.4

N/A

BOL?

Exception –

600L Emulation:

OOL?

BOL=xx.x

(see Description of

Arguments)