beautypg.com

1 d&i primary data interfaces, 2 d&i framing – Comtech EF Data CDM-625 User Manual

Page 374

background image

CDM-625 Advanced Satellite Modem

Revision 15

Open Network Operations

MN-CDM625

14–4

14.3.1 D&I Primary Data Interfaces

When configured for D&I operation, multiplexing/demultiplexing follows the IBS satellite frame

structure and ESC features, but with the following changes:

• It accepts and outputs primary data through the G.703 connectors.

• The data rate must be at T1 or E1 rates only. This includes additional links for Drop Data Out

and Insert Data In.

• Clock recovery, dejitter, and encoding/decoding are performed as before.

14.3.2 D&I Framing

The IBS satellite framing/deframing is applied only to selected time slots of the data’s G.704

terrestrial structure.