CDM-625 Advanced Satellite Modem
Revision 15
Front Panel Operation
MN-CDM625
5–50
If selecting Local, then reconfiguration via Serial Remote or Ethernet is not permitted although
remote monitoring is still possible. If Local or Serial Remote selected, a typical submenu is
displayed – proceed to the next section.
5.2.1.12.1 CONFIG: Remote Local or Serial remote settings
Interface= RS-485-4W (232,485-2,485-4)
Address= 0001 9600 baud
()
If selecting either Local or Serial remote control, use the
◄ ►
arrow keys to select Interface,
Address, or Baudrate; then, use the
▲▼
arrow keys to edit the Interface type, Baudrate, and
each digit of the Address. Note the following:
•
Character format is not selectable and is fixed at 8-N-1.
•
For RS-485 (aka EIA-485) – The permitted address range is from 0001 to 9999. Address 0000
is reserved for universal addressing.
•
For RS-232 (aka EIA-232): The Address is fixed at 0000.
5.2.1.13 CONFIG: IP
IP Config: Addresses SNMP Setup
ANT AccessList PktP-Enable ()
Use the
◄ ►
arrow keys to select Addresses, SNMP, Setup, ANT, AccessList, or – displayed only
when the optional IP Packet Processor card is installed – PktP-Enable, and then press ENTER.
5.2.1.13.1 CONFIG: IP Addresses
IP Addresses: MAC Gateway
Addr/Range
()
Use the
◄ ►
arrow keys to select MAC, Gateway, or Addr/Range, and then press ENTER.
CONFIG: IP Addresses MAC
Ethernet MAC Address:
00-06-B0-00-01-06
(read-only)
This read-only screen displays the unit MAC address. Press ENTER or CLEAR to return to the
previous menu.