F.2 ODU Remote Control Address Setup
The ODU, as connected to a CDM-625 through FSK (Frequency Shift Keying), can be remotely
monitored and controlled through the use of ODU commands and queries issued via serial
remote control or with the Telnet Command Line Interface (CLI).
The address of the ODU is set up as follows:
• For Local-End ODUs:
o Use the Modem’s RC Address + 1 for a Standalone Unit or the Online Unit in a 1:1
Redundancy System;
o Use the Modem’s RC Address + 2 for the Offline Unit in a 1:1 Redundancy System.
• For Distant-End ODUs in an EDMAC setup:
• Chapter 11. EDMAC CHANNEL
• Appendix D. REMOTE CONTROL
o Use the EDMAC Slave Address (ESA) Range +4 for Standalone Unit or the Online Unit in a
1:1 Redundancy System;
o Use the EDMAC Slave Address (ESA) Range +5 for the Offline Unit in a 1:1 Redundancy
System.