CDM-625 Advanced Satellite Modem

Revision 15

Installation

MN-CDM625

2–2

Once opened, inspect the shipment:

Step

Task

1

Keep all shipping materials.

2

Check the packing list to make sure the shipment is complete.

3

Inspect the equipment for damage. If damage exists, immediately contact the carrier

and Comtech EF Data to submit a damage report.

4

Read the manual.

2.2 Install the Unit Into a Rack Enclosure

Mount The unit in its assigned position in the rack enclosure (Figure 2-2):

Use, as required:

• A standard rack-mounted shelf;

• User-supplied screws to secure the front panel to the rack enclosure threaded front

mounting rails;

• Comtech EF Data’s optional KT/6228 (4”) or KT/6228 (10”) Rear-Mounting Support Brackets

Kit (Figure 2-3).

CAUTION – When mounting The unit into a rack enclosure:

PROPER GROUNDING PROTECTION IS REQUIRED. The equipment must be connected

to the protective earth connection at all times. It is therefore imperative that the unit

is properly grounded, using the ground stud provided on the unit rear panel, during

installation, configuration, and operation.

o In Finland: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun

pistorasiaan."

o In Norway: “Apparatet må tilkoples jordet stikkontakt.”

o In Sweden: “Apparaten skall anslutas till jordat uttag.”

PROPER AIR VENTILATION IS REQUIRED. In a rack system where there is high

heat discharge, provide forced-air cooling with top- or bottom-mounted fans or

blowers.

o Make sure there is adequate clearance inside the enclosure, especially at the

side for air ventilation.