Follow these steps to install the optional KT/6228 (4”) or KT/6228 (10”) Rear-Mounting Support

Brackets Kit:

Step

Task

1

Use the #10 flat washers, #10 split washers, and #10 hex nut to secure the #10 shoulder screws to the unit

chassis through the rear right and left side mounting slots as shown.

2

Use the #10 rack bracket bolts to install the rear support brackets onto the rack enclosure threaded rear

mounting rails.

3

Mount the unit into the rack enclosure. Ensure that the shoulders of the #10 shoulder screws properly engage

into the rear support bracket slots.

2.3 Configure the CDM-625

Chapter 5. FRONT PANEL OPERATION

The unit is shipped with a default 64 kbps, QPSK, Rate 1/2 configuration. There are no internal

jumpers to configure, no interface cards to install, and no other options to install. Conifugration is

carried out entirely via the modem’s installed firmware – use the front panel keypad and display to

configure the modem locally.

The auto-sensing AC power supply does not require any adjustments. Simply plug in

the supplied line cord, and turn on the rear panel switch.

2.4 Verify Modem Operation

Chapter 5. FRONT PANEL OPERATION – Sect. 5.2.2 SELECT: Test Menus

You may use the modem’s test functions to quickly verify proper operation of the modem,

without the need for externally connected equipment. Use the front panel keypad and, from the

top level menu, select TEST: Mode →

IF (

IF LOOP).The demod should synchronize, and the Rx

TRAFFIC LED should illuminate GREEN. If the unit does not pass this test, contact Comtech EF

Data Product Support for further assistance.

2.5 Connect the External Cables

Chapter 3. REAR

PANEL

CONNECTORS

AND

PINOUTS

Once you verify correct operation via the Internal IF Loop test, use the front panel keypad to

finalize your configuration as needed. Connect all external cables. If difficulties occur, contact