Rear Panel Connectors and Pinouts

MN-CDM625

3–14

3.2.3.4 1:1 Control (DB-9F)

The 1:1 Control connector is intended only for connection to a CRS-170A or CRS-180

Redundancy Switch.

The 1:1 Control connector is a 9-pin Type ‘D’ female connector.

Table 3-14. 1:1 Control Interface Connector Pinouts

Pin #

(R-L) Description

Direction

1 Ground

6

Transmit Serial Data – auxiliary channel

Out

2 Receive Serial Data – auxiliary channel

In

7

Redundancy Out 1

Out

3 Redundancy In 1

In

8

Redundancy Out 2

Out

4 Redundancy In 2

In

9

Fused +12 volt Out

Out

5 Ground

3.2.3.5 Ext Ref In/Out

Connector Type

Description

Direction

BNC

External Reference

In/Out