CDM-625 Advanced Satellite Modem

Revision 15

Front Panel Operation

MN-CDM625

5–5

Sect. 7.6 Turbo Product Codec (Hardware Option)

Sect. 7.7 TPC and Low Density Parity Check (LDPC) coding

DoubleTalk Carrier-in-Carrier Module – If installed and enabled, the presence of CnC is

indicated with the appearance of the flashing CnC icon on the following front panel SELECT:

menus: CONFIG CnC; Test; Info; and Monitor.

Chapter 10. DOUBLETALK CARRIER-IN-CARRIER OPTION

VersaFEC Card – If installed, the display also indicates VFEC.

Sect. 7.8 VersaFEC (Short-block LDPC)

IP Packet Processor Card – If installed, the display also indicates PktP.

Chapter 18. IP PACKET PROCESSOR OPTION

CDM-600/600L Emulation Indication – The CDM-625 serves as a ‘drop-in’ replacement

product for CDM-600 and CDM-600L modems. An emulation mode is provided to

accomplish this design intent, and is configurable via either the front panel (SELECT:

UtilityEm) or by remote control (remote command EMU=).

When emulating a CDM-600 or CDM-600L modem, the UNIT opening screen displays the

mode of operation, as per this example:

Comtech CDM-625 emulating a CDM-600

TPC,CnC,VFEC,PktP present Ver2.2.6

Note that, while emulating a CDM-600 or CDM-600L modem, the I/O responses (including

that of remote query EID?) replicate those of the emulated modem; further, the firmware

version number displayed on the opening screen, and the response from the SWR? remote

query reflects that of the emulated modem’s firmware version number.

Warm-up Delay Mode counter – When selecting the warm-up delay mode, the modem

turns the carrier off during the warm-up time and the countdown message “

High-

Stability Ref Warming up: ### sec displays on the bottom line of the screen

as follows:

Comtech CDM-625 emulating a CDM-600

High-Stability Ref warming up: 009 sec