7 config: tx ( symb (ip-acm mode only), Config: tx tx data tx sub-mux, 7 config: tx symb (ip-acm mode only) – Comtech EF Data CDM-625 User Manual
Page 119
CDM-625 Advanced Satellite Modem
Revision 15
Front Panel Operation
MN-CDM625
5–19
Note that in QDI (Quad D&I) mode, these data rates are read-only! The data rate is the sum of
the tributary rates for all ports. You must edit them via the QDI menu.
On the bottom line – To set the Data Invert or Clock Invert operation, for either, use the
▲▼
arrow keys to select On or Off. Press ENTER when done.
CONFIG: Tx Tx Data Tx Sub-Mux
Tx Sub-Mux = Off (Off, On)
Ratio = 1/9 (IP/Synchronous) ()
Use the
▲▼
arrow keys to select the desired ratio, and then press ENTER. There are a total of
34 ratio options available:
► 1/59
► 1/39
► 1/19
► 1/9
► 1/8
► 1/7
► 1/6
► 1/5
► 1/4
► 2/7
► 1/3
► 2/5
► 3/7
► 1/2
► 3/5
► 2/3
► 3/4
► 4/5
► 1/1
► 5/4
► 4/3
► 3/2
► 5/3
► 2/1
► 7/3
► 5/2
► 3/1
► 7/2
► 4/1
► 5/1
► 6/1
► 7/1
► 8/1
► 9/1
5.2.1.3.7 CONFIG: Tx Symb (IP-ACM Mode Only)
Chapter 17. ADAPTIVE CODING AND MODULATION (ACM)
VersaFEC ACM requires the correct hardware module (PL-0000264) to be installed in
the unit; Version 1.4.0 (or higher) firmware; and the appropriate FAST code for the
maximum operating symbol rate.
TxSymbolRate = 01000.000 ksps (ACM Mode)
Data Invert=Off Clock Invert=Off ()
Take care to note that the use of IP-ACM is a fundamental departure from the way you would
typically configure the modem. When IP-ACM mode is active, the CONFIG: Tx menu changes the
Data option to Symb.
Use the
◄ ►
arrow keys to select TxSymbolRate, Data Invert, or Clock Invert, and then press
ENTER.
On the top line – To edit the Tx Symbol Rate, use the
◄ ►
arrow keys to first select the digit to
edit, and then use the
▲▼
arrow keys to change that digit. Press ENTER when done.
On the bottom line – To edit the Data Invert or Clock Invert: For either, use the
▲▼
arrow keys
to select On or Off, and then press ENTER.