beautypg.com

Comtech EF Data CDM-625 User Manual

Page 520

background image

CDM-625 Advanced Satellite Modem

Revision 15

Appendix D

MN-CDM625

D–56

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to

Query

CnC-APC

Home State

AHS=

12 bytes

Command or Query.

Command is only for Offline unit in Redundancy system, sent by 1:N switch or Online unit in 1:1 system.

Returns CnC-APC home state parameters in the form a,bbb,cc,ddd, where:

a = APC state. (1 = APC is active, 0 = APC is not active)

bbb = APC home state Tx power, in 0.1dB. (minus sign assumed)

cc = APC home state max power level increase, in 0.1 dB.

ddd = APC Tx power threshold, in 0.1 dB. (minus sign assumed)

Example: AHS=1,100,60,085 (APC is active, home state power is -10.0 dB, home state max power level

increase is 6.0 dB, power threshold is -8.5 dB)

AHS=

AHS?

AHS*

AHS#

AHS?

AHS=a,bbb,cc,ddd

(see Description of

Arguments)

ACM Remote

Signal Noise

Ratio

N/A

4 bytes

Query only.

Returns the value of SNR of the remote demod in the form xx.x, where:

99.9 = Demod is unlocked.

xx.x = Not in IP-ACM.

Example: RSN=12.4

N/A

RSN?

RSN=xx.x

(see Description of

Arguments)

ACM Local

Signal Noise

Ratio

N/A

4 bytes

Query only.

Unit returns the value of Local Signal Noise Ratio in the form xx.x, where:

99.9 = demod is unlocked.

xx.x = Not in IP-ACM, Resolution 0.1 dB.

Example: SNR=12.3 (selects SNR=12.3 dB)

N/A

SNR?

SNR=xx.x

(see Description of

Arguments)

Uncorrected

BER

N/A

7 or 8 bytes

Query only.

Units returns the value of the uncorrected BER.

LT = less than

GT = greater than

Returns 9999999 if the demodulator is unlocked or uncorrected BER data is unavailable.

Example: BER=4.3E-02 BER=GT1.0E-1

N/A

RBE?

RBE=xxxxxxxx

(See Description of