Comtech EF Data CDM-625 User Manual
Page 507

CDM-625 Advanced Satellite Modem
Revision 15
Appendix D
MN-CDM625
D–43
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to
Query
…Global
Configuration
(cont.)
ee=Compressed Ethernet port speed
E=Attach summary BUC alarm to Tx
F=Attach summary LNB alarm to Rx
GGG=WAN buffer length
H=Dedicated Management Port
see **
same as ABA
same as ALA
same as WBL
same as DMP
Note: Much of the 625 MGC format has been kept similar to the 600/L MGC format.
* indicates differences.
** Ethernet port speed is compressed from 4 bytes in SEC command to 2 bytes in MGC. First byte
represents speed settings for Port 1 and Port 2, second byte represents speed settings for Port 3 and Port
4. In each byte, character A through Y is used to represent 25 possible combinations of two port speed.
A=00, B=01, C=02, D=03, E=04, F=10, G=11, H=12, I=13, J=14, K=20, L=21, M=22, N=23, O=24, P=30,
Q=31, R=32, S=33, T=34, U=40, V=41, W=42, X=43, Y=44.
Example: BN is converted to 0123, that means Port 1 is AutoNeg, Port 2 is 100Full, Port 3 is 100Half, Port
4 is 10Full.
OGC Outdoor
Unit Global
Copy
OGC=
50 Bytes
Command or Query.
ODU Global Configuration of CDM-625, in the form shown in the Response to Query column (to the right), where:
OGC=
OGC?
OGC*
OGC#
OGC?
OGC?n (where n
= 0 to 9. Returns
the OGC portion
of 1 of 10 stored
configurations)
OGC=aabxdexxxxxg
ggghhhhxxxxixklllnn
nFFFFFSfffffsxxxxxx
(Returns current
OGC Configuration)
aa=BUC Address
b=BUC Tx Output Enable
* x (spare)
d=BUC Power Supply
e=BUC 10MHz Reference State
xxxxx (spares)
gggg=BUC Current - Low Limit
hhhh=BUC Current - High Limit
* xxxx (spares)
* i=LNB Power Supply
* x (spare)
k=LNB 10MHz Reference
lll=LNB Low Alarm Limit
nnn=LNB High Alarm Limit
FFFFFS=TX LO Frequency
fffffs=RX LO Frequency
xxxxxx (spares)
same as BAD
same as BOE
same as BPS
same as BFR
same as BCL
same as BCH
same as LPS
same as LNR
same as LNL
same as LNH
same as TLO
same as RLO
Notes:
1. Much of the 625 OGC format has been kept similar to the CDM-600L OGC format (* indicates the
differences). In 600L Emulation Mode, OGC follows the CDM-600L’s OGC format.
2. Any unavailable parameters will be filled with x’s.