beautypg.com

Comtech EF Data CDM-625 User Manual

Page 488

background image

CDM-625 Advanced Satellite Modem

Revision 15

Appendix D

MN-CDM625

D–24

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to

Query

Rx Clock

Source

RCK=

1 byte, value

of 0 thru 3

Command or Query.

Rx Clock Source in the form x, where:

0=Rx Satellite

1=Tx-Terrestrial

2=Internal(SCT)

3=INSERT (command valid only when Rx framing is Insert or D&I++ and interface is G.703 or set for

D&I loop)

Example: RCK=1 (selects Tx-Terrestrial)

RCK=

RCK?

RCK*

RCK#

RCK?

RCK=x

(see Description of

Arguments)

Rx Clock

Invert

RCI=

1 byte, value 0

or 1

Command or Query.

Invert Receive Clock, in the form x, where:

0=Normal

1=Inverted

RCI=

RCI?

RCI*

RCI#

RCI?

RCI=x

(see Description of

Arguments)

Eb/No Alarm

Point

EBA=

4 bytes

Command or Query.

Eb/No alarm point in dB, with a range between 0.1 and 16 dB, in the form xx.x, where:

Resolution=0.1 dB
Example: EBA=12.3

EBA=

EBA?

EBA*

EBA#

EBA?

EBA=xx.x

(see Description of

Arguments)

Rx Buffer

Size

RBS=

5 bytes

Command or Query.

Rx Buffer Size, 16 to 32768 bytes, in 2-byte steps, unless other limitations apply.

(See Sect. 5.3.1.5.2)
Example: RBS=08192 (selects 8192 bytes)

RBS=

RBS?

RBS*

RBS#

RBS?

RBS=xxxxx

(see Description of

Arguments)

Rx Audio

Volume

Control

RVL=

4 bytes

Command or Query. (Audio/IDR parameters)

Rx Audio Volume control, in the form aabb, where:

aa=Rx 1 volume control in dB, valid values are -6, -4, -2, +0, +2, +4, +6, +8;

bb=Rx 2 volume control in dB, valid values are -6, -4, -2, +0, +2, +4, +6, +8.
Example: RVL= -2+4 (sets Rx 1 to -2 dB and Rx 2 to +4 dB)

RVL=

RVL?

RVL*

RVL#

RVL?

RVL=aabb

(see Description of

Arguments)

Receive

Terrestrial

Alarm Enable

RTE=

1 byte, 0 or 1 Command or Query. (INSERT mode parameter)

Receive Terrestrial Alarm Enable conditions in the form x, where:

0=Disables the alarm

1=Enables the alarm.

Example: RTE=0 (disables the alarm).

RTE=

RTE?

RTE*

RTE#

RTE?

RTE=x

(see Description of

Arguments)

Insert Type

ITY=

1 byte, value

of 0 thru 3

Command or Query. (INSERT/D&I++/QDI parameter)

Insert Type, in the form x where:

0=T1–D4

1=T1–ESF

2=E1–CCS

3=E1–CAS

ITY=

ITY?

ITY*

ITY#

ITY?

ITY=x

(see Description of